banner

Deicing Products > Aircraft > Kilfrost ABC-S

Sampling Procedure
For Kilfrost ABC-S and/or ABC-S Plus Type IV Aircraft Fluid
(PDF)

Section One to be used when sampling Kilfrost ABC-S and/or ABC-S Plus Type IV aircraft fluid trucks or containers.
Section Two to be used when testing shear of Type IV fluids from equipment nozzles.


Section One
Equipment Needed:

Procedure:

  1. Open container hatch and flush sampler by lowering sampler to sample depth. Allow sampler to fill, and then drain sampler back into tank.
  2. Collect sample by lowering sampler to approximately 3 feet below liquid surface and allow sampler to fill. Remove sampler and empty contents into sample bottle.
    Note: If product color is not green, stop sampling and contact Cryotech before shipping!
  3. Repeat sampling until approximately a 1 liter sample has been collected. Allow some head space in bottle.
  4. After collecting sample, hatch must be properly closed, latched and sealed.
  5. Cap sample bottle, clean bottle exterior and label properly with:
    • Date sampled
    • Product Name - Kilfrost ABC-S and/or ABC-S Plus
    • Sample location
    • Name of person drawing sample
    • Original container number
    • Container number
    • Seal number
  6. Tighten container cap (being careful not to break it), seal with tape, and place in a 1 gallon zip lock bag and package according to DOT requirements. Ship by courier service to:
    • Cryotech Deicing Technology
      6103 Orthoway
      Fort Madison, IA 52627
      ATTN: QC Lab
      Phone: +1 319-372-6012

Section Two
Equipment Needed:

Procedure:

  1. Insert a clean 55 gallon black plastic bag into the drum or tote.
  2. Tie the plastic bag (using string or rubber bands) around the nozzle to prevent deicing fluid from being sprayed outside of a controlled area.
  3. Start equipment as you would for a Type IV deicing operation with pumps at factory setting.
  4. FULLY OPEN the nozzle for several seconds to discharge fluid into the plastic bag. (For equipment with common nozzles for Type I and Type IV, flush any Type I from the nozzle into a separate plastic bag, before this step.)
    NOTE: It is CRITICAL the nozzle be fully open when taking this sample. A partially open nozzle will shear the fluid and will require retesting.
  5. Collect one (1) liter of fluid from the plastic bag and refer to the shipping procedures in Steps 5 and 6 in Section 1.
  6. Dispose of remaining Type IV fluid in accordance with airport environmental requirements.